Looking for an HVAC company you can trust in the Fuquay-Varina, NC area? Comfort Pro provides expert trustworthy heating and AC services to your area. We’ve been helping your neighbors with their home comfort since 2013 and have decades of experience in the industry. We invite you to read some of our reviews below to learn more about our company and services. Our customers are our biggest champions and we love to show off what they say about our services! If you live in the Fuquay-Varina, NC area, we would love to help you with your central AC or heating system today!
Recent Jobs and Reviews in Fuquay-Varina, NC
Our Local Reviews by City
- Angier, NC (4)
- Apex, NC (23)
- Cary, NC (25)
- Chapel Hill, NC (5)
- Clayton, NC (3)
- Durham, NC (5)
- Fuquay-Varina, NC (32)
- Garner, NC (2)
- Holly Springs, NC (55)
- Knightdale, NC (3)
- Lillington, NC (1)
- New Hill, NC (1)
- Pittsboro, NC (3)
- Raleigh, NC (30)
- Siler City, NC (1)
- Wake Forest, NC (2)
- Wendell, NC (1)
Job Locations and Reviews
I replaced an outdated AC system with a new American Standard Silver 16 two-stage unit. The old system was inefficient and struggling to cool the home. After disconnecting the old unit, I installed the new condenser and a matching American Standard evaporator coil. I replaced the refrigerant lines and ensured the system was properly charged. The unit was calibrated, and the thermostat was adjusted for optimal efficiency. The new system is now cooling the home effectively and is more energy-efficient.
I performed an air duct cleaning on a commercial system using a Rotobrush system. The ducts were clogged with dust and debris, affecting airflow. I cleaned the supply and return vents, removed dirt from the duct walls, and sanitized the system with an antimicrobial treatment. This improved both airflow and indoor air quality throughout the building.
I performed fall maintenance on a Carrier Infinity 20 25VNA0 heat pump system in preparation for the colder months. I inspected and cleaned the outdoor coil using Nu-Calgon Evap Foam No Rinse, checked refrigerant charge, and updated firmware on the Carrier Infinity Touch thermostat. I replaced the air filter with a MERV 13 pleated filter, tested the auxiliary heat strips, and verified proper defrost cycle operation. I also inspected the heat pump's reversing valve and lubricated the fan motor bearings. System efficiency and cold weather performance were optimized.
I installed an Aprilaire 5000 whole-house air purifier in a residential HVAC system. I integrated it with the existing ductwork, ensuring proper airflow. I wired the unit to the HVAC control board and programmed the PureFilters control panel. I used a duct traverse method with an anemometer to verify that airflow remained within acceptable ranges after installation.
I completed an HVAC cooling repair for a customer experiencing inconsistent cooling. After inspecting the system, I discovered a faulty blower motor in the air handler. I replaced the old motor with a new OEM replacement, ensuring proper alignment and connection to the blower wheel. Once installed, I tested the system to confirm that the airflow was restored, and the cooling performance was consistent.
A customer reported water leaking from their HVAC unit. Upon inspection, we found a clogged condensate drain line and a damaged drain pan. We cleared the blockage using a wet/dry vacuum and replaced the drain pan with a new one to ensure proper drainage. The unit, a Trane XR14, was then tested to confirm the leak was resolved. Regular maintenance can prevent such issues and ensure efficient operation of your HVAC system.
We addressed an issue with an AC unit that was cycling on and off too frequently. After a thorough inspection, we identified a faulty thermostat and low refrigerant levels as the main causes. We replaced the thermostat with a new Honeywell T6 Pro model and recharged the system with R-410A refrigerant. Additionally, we checked and cleaned the evaporator coils to ensure optimal airflow. These steps restored proper function and efficiency, preventing the AC from short cycling. Trust our team for expert AC repairs and maintenance.
We recently completed a repair on a Lennox XC21 air conditioning unit that was not cooling effectively. Our inspection revealed a faulty contactor and low refrigerant levels. We replaced the defective contactor with a Lennox 10C81 relay contactor and recharged the system with R-410A refrigerant. Additionally, we cleaned the evaporator coils to ensure optimal airflow and efficiency. This repair restored the unit’s cooling performance and reliability. For expert AC repairs and maintenance, trust our experienced team.
Responded to emergency call for inoperative 3-ton Trane heat pump. Diagnostic tests revealed failed compressor due to seized scroll mechanism. Recovered remaining R-410A refrigerant and removed defective compressor. Installed new 36,000 BTU reciprocating compressor, replacing liquid line filter drier and Schrader valves. Pressure tested system to 400 PSI with nitrogen. Evacuated to 250 microns and recharged to factory specifications. Verified proper operation of reversing valve and defrost control board. Measured superheat and subcooling, confirming optimal charge. System restored to full cooling and heating capacity.
Conducted comprehensive annual AC maintenance on 5-ton Carrier split system. Inspected and cleaned condenser and evaporator coils using non-acidic foam cleaner. Checked refrigerant charge, confirming proper subcooling at 10°F. Tested capacitor microfarad ratings and replaced weak start capacitor. Cleaned and tightened electrical connections, verifying amp draw on compressor and fan motors. Lubricated bearings and adjusted belt tension on air handler. Flushed condensate line with nitrogen and installed algaecide tablet. Replaced 4-inch MERV 11 filter and calibrated digital thermostat. System efficiency improved by 15% post-service.
Installed American Standard AccuClean Whole-Home Air Cleaner, model AAFCC2A01 on existing HVAC system. Mounted unit in return air duct. Wired to dedicated 24V transformer for independent operation. Installed reusable collecting cells and prefilter. Configured system to maintain optimal airflow across filter media. Adjusted fan speed to compensate for increased static pressure (0.35" w.c.). Tested system performance using particulate meter, confirming 99.98% efficiency in capturing particles down to 0.1 microns. Demonstrated CleanEffects technology operation to homeowner.
Conducted AC repair on a Carrier Infinity 21 unit. Diagnosed a refrigerant leak in the evaporator coil and a malfunctioning capacitor. Repaired the leak, recharged the system with R-410A refrigerant, and replaced the faulty capacitor. Cleaned the condenser coils and checked the electrical connections. Tested the system for optimal superheat and subcooling values, ensuring efficient and reliable cooling performance for the homeowner.
Performed an AC tune-up in Fuquay Varina. Inspected and cleaned the condenser and evaporator coils, checked refrigerant levels, and tested the thermostat calibration. Lubricated moving parts and tightened electrical connections. Verified system pressures and temperatures for optimal efficiency. Ensured the AC unit operates smoothly, reducing the risk of breakdowns and improving energy efficiency.
Repaired an AC unit by addressing a refrigerant leak. Located the leak using a UV dye and leak detector. Repaired the damaged section of the refrigerant line and recharged the system with R-410A. Tested the system for further leaks and ensured proper refrigerant levels. Verified optimal cooling performance and system efficiency after the repair.
I responded to a no-cooling call and discovered a failed compressor on a 3-ton air-cooled condensing unit. I recovered the remaining R-410A refrigerant per EPA protocols, replaced the compressor, expansion device, filter drier, and gaskets, evacuated the system to 500 microns, charged with 7 pounds of virgin R-410A, checked subcooling and superheat, adjusted the charge, cleaned the condenser coils, cycled the system through heating and cooling modes, and the unit is now operating within manufacturer's specifications with proper refrigerant charge, airflow, and temperatures.
I repaired a Trane XR15 heat pump that was not cooling properly due to a faulty reversing valve. Diagnosed the issue and confirmed the valve was stuck. Replaced the malfunctioning reversing valve with an OEM part. Evacuated and recharged the refrigerant system, ensuring proper levels. Tested the heat pump for efficient cooling operation. The Trane XR15 is now back to optimal performance, providing reliable cooling.
I fixed an HVAC problem in Fuquay Varina this morning by changing the unclean air filter and fixing the broken blower motor. To make sure everything worked well together, I utilized a customized HVAC motor. With this repair, the system's overall temperature management and airflow were restored, improving the unit's performance and guaranteeing a pleasant interior atmosphere. Periodic inspections and upkeep are essential for the longevity of the system. A quote for installing a whole-house air purification system was also provided.
Today, I repaired a Lennox XC21 air conditioner with a faulty capacitor. Diagnosed the issue as a failed run capacitor, causing the compressor to malfunction. Replaced the defective capacitor with a new 45+5 MFD dual run capacitor. Verified the integrity of electrical connections and tested the system for optimal cooling performance. The Lennox XC21 is now running efficiently, ensuring reliable cooling for the client's home.
I repaired an Aprilaire Model 5000 whole-home air purifier today. I replaced the dirty MERV 16 filter cartridge with a new genuine Aprilaire 201 filter. Using a soft brush, I cleaned the ionizer wires and collector plates. Finally, I reset the service reminder light and verified proper airflow.
In Fuquay this morning finishing up sealing air ducts in a customer's home. The ducting was flexible fiberglass. I inspected for leaks and used mastic sealant to cover gaps and joints. Additionally, I applied foil tape to reinforce the connections. I also replaced damaged sections with new R6 insulated flexible ducting. The entire system was then tested, showing improved airflow and no leaks, ensuring optimal HVAC performance.
I performed annual maintenance on a Carrier 24ABC6 air conditioner and 58MVP090 gas furnace system today. Replaced the 16x25x1 air filters. Cleaned the condenser coils using Nu-Calgon CalClean. Checked refrigerant pressures and added 12 oz of R-410A to attain 310 psi. Tested safety controls and tightened electrical connections. Lubricated the blower motor with Supco SP10 lubricant.
Upon receiving the customer's request for a quote, I conducted a comprehensive evaluation of their HVAC system and ductwork. After assessing the unit's size, efficiency, and duct condition, I provided a detailed estimate for a new HVAC system installation, including necessary duct repairs. The proposal outlined the recommended equipment specifications and anticipated labor and material costs for a complete and efficient heating and cooling solution.
Upon investigating the customer's report of no cool air and a musty odor from the air vents, I conducted a thorough inspection of the HVAC system. My examination revealed a clogged air filter, restricting airflow and promoting mold growth. I replaced the filter and proceeded to clean the evaporator coil and drain pan to eliminate the musty smell. Additionally, I recommended scheduling routine maintenance to prevent future issues and ensure optimal system performance.
During today's inspection of the HVAC system, I observed the following: Delta T indicates a favorable split of 25° between return air temperature (75°) and supply air temperature (50°), meeting acceptable standards. External Static Pressure testing wasn't necessary for this unit. The absence of a condensate safety switch was noted. The compressor run capacitor falls within tolerance levels. The condenser fan run capacitor is in good condition, while the blower run capacitor is not applicable. I advised the homeowner on the importance of cleaning the dirty blower wheel to preserve the motor's lifespan and emphasized the necessity of regular condenser coil maintenance. Overall, the system is functioning well, with maintenance attention needed for the blower wheel.
Updating an outdated cooling system, I replaced a 20-year-old Trane air conditioner with a newer, more efficient model. The installation involved removing the old unit, configuring the new system to match existing ductwork and electrical connections, and ensuring proper refrigerant charge. The upgraded unit boasts advanced features such as variable-speed technology and higher SEER ratings, providing improved comfort and energy savings for the customer's home.
We are glad that you loved our services, our dedicated staff will be pleased to learn of your high praise.
Thank you so much for taking the time to leave an excellent rating. We really appreciate your business.
Thank you so much for taking the time to leave an excellent rating. We really appreciate your business.
We are so grateful for your 5-star review. Thanks for sharing your rating with us and the community.
Thanks for sharing your review with us and the community.
Thank you so much for taking the time to leave us a 5-star review!
We are incredibly grateful that you took the time out to leave us a 5-Star review.
Thanks for leaving us such a wonderful review. We are glad that you loved our services, our dedicated staff will be pleased to learn of your high praise.
Thank you so much for your 5-star review! We will share this with the team to let them know to keep up the amazing work.
We're so glad you had a positive experience with us. Thank you for your kind words and support.
We're delighted to hear that you had a positive experience with us. Thanks for the kind words.
We're so happy to hear that you had a great experience with us. Thanks for leaving a positive review.
Thank you for allowing Comfort Pro to handle your HVAC maintenance and inspect your air conditioner. We are happy we could get you ready for summer.
Thank you so much for your 5-star review! We will share this with the team to let them know to keep up the amazing work.
We're delighted to hear that you had a positive experience with us. Thanks for the kind words.
Thank you so much for your 5-star review! We will share this with the team to let them know to keep up the amazing work.
We are so grateful for your 5-star review. Thanks for sharing your rating with us and the community.
Your kind words mean a lot to us. Thanks for leaving such a positive review!
Thanks for leaving us such a wonderful review. We are glad that you loved our services, our dedicated staff will be pleased to learn of your high praise.
Your kind words mean a lot to us. Thanks for the positive feedback.
We are so grateful for your 5-star review.
We are incredibly grateful that you took the time out to leave us a 5-Star review.
Thank you so much for your 5-star review! We will share this with the team to let them know to keep up the amazing work.
Thank you so much for taking the time to leave an excellent rating. We really appreciate your business.
We are so grateful for your 5-star review. Thanks for sharing your rating with us and the community.